Clark Reliance Water Columns — Cast Iron & Steel — Northeast Controls Inc.

Clark Reliance — Boiler Controls

Cast Iron Water Columns

For Pressures 0 to 250 psi

Clark-Reliance water column

Clark-Reliance® Water Columns

Clark-Reliance manufactures a small, cast iron, float type water column and a larger size cast iron water column that can be either float type or probe type (Universal Column W0250). Available in high pressure and low pressure configurations for boiler water level indication.

Clark-Reliance manufactures a small, cast iron, float type water column and a larger size cast iron water column that can be either float type or probe type (Universal Column W0250). To select the proper water column model, first acquaint yourself with the types of columns available, then:

  • Determine the gage glass visibility required.
  • Determine the steam and water center dimension.
  • Determine the alarm variation requirements.
  • List the alarm/control functions desired.

Material Note: The cast iron used in Clark Reliance Column 1 and W0250 water columns is ASTM A278-CL30. For recommended installation procedures, refer to Catalog 500, Section AB2.4. The lowest visible part of water gage glass must be at least 2 inches above the lowest permissible boiler water level.

Column 1 — Float Type

Small Column Size · Fixed Dimensions · Fixed Connection Locations · Alarm Function Only

Column 1 is a comparatively small water column in regard to water gage center measurements and other related dimensions. Column 1 is available only with 1" or 1½" steam and water connections.

Float Type Water Column — W0250

Variable Gage Centers · Variable Steam/Water Locations · Alarm Function Only

Column W0250 provides water gage centers that can vary upon specification from 13½" to 23". Top or side steam and water connections can vary upon specification from 11½" to 22".

Conversion Columns: All Clark-Reliance cast iron, float type columns serving pressures to 250 PSI can be converted to accommodate a probe cap. This conversion brings fuel cut-out controls, as well as high/low alarms, to converted columns.

Probe Type Water Column — W0250-EA4

Variable Gage Centers · Variable Steam/Water Locations · Alarm & Fuel Cut-Out Functions

Column W0250-EA4 offers the same variations in water gage centers and steam/water connections as Column W0250-FA. In addition, W0250-EA4 also provides probe actuated high/low alarms and low fuel cut out control.

Column W0250-EA3 provides probe actuated high/low alarms only.

Probe Type Water Column — W0250-EA5 / EA6

Variable Gage Centers · Alarm & Fuel Cut-Out & Pump Control Functions

Column W0250-EA6 offers the same variations in water gage centers and steam/water connections as Column W0250-FA. In addition to probe actuated high/low alarms and low fuel cut-out functions, this column also provides probe controlled pump actuation. Column W0250-EA5 provides probe actuated high/low alarms in combination with low and high fuel cut-out.

Model Selection Guide

ModelFloat TypeProbe TypeHigh AlarmLow AlarmFuel Cut-Out
COLUMN 1XX
W0250-FAXX
W0250-EA3XX
W0250-EA4XXX
W0250-EA5XXX
W0250-EA6XXXX

Need help selecting the right water column?

Our team can assist with product selection, sizing, and replacement parts.