RCM Flo-Gage™ Construction, Materials & Options — Northeast Controls Inc.

RCM Flow Meters

Flo-Gage™ Construction & Options

Materials of Construction · Series 7000 & 8000 · Full Options Index

Key Features

  • Sturdy in-line metal construction to withstand piping stresses without breaking
  • Black on white dial — won't crack, glaze or become hard to read with age
  • Expanded 3.5″ (90mm) 270° analog dial for reading at a glance
  • Suitable for use with both opaque and clear fluids
  • 6:1 turndown ratio with ±3% F.S. accuracy, ±1% repeatability
  • Dial and case factory configured for quick installation — easily field re-configured if needed
  • Self-contained — no external power, separate orifices, or blocking valves required
  • Available with limit switches, transmitters, digital displays, and remote mountings
  • Works with liquids, gases, and saturated steam in a single product family
RCM Flo-Gage variable area flow meter — 316SS wafer body with analog dial and flow direction arrow

Flo-Gage™ — 316SS Wafer Body, Series 7000

Series 7000 & 8000 — Body Styles

SeriesConnectionSizesFlange ClassNotes
Series 7000Threaded FNPT1/4″ – 3″NPT or BSP connections
Series 8000Wafer (flanged)1/2″ – 8″150 / 300 classMounts between standard flanges

Materials of Construction & Specifications

Component / ParameterStandardOptional
HousingUV Stabilized PolycarbonateAluminum
BodyBronzeMonel · 316SS
BellowsBronzeMonel · 316SS · Inconel
SealsBuna-NViton · EPR · Teflon
CrystalPolycarbonateGlass
Gear MovementBronze316SS
Accuracy±3% F.S.±3% F.S.
Repeatability±1% F.S.±1% F.S.
Pressure Max (std)180 psig (12.6 kg/cm²)400 psig (28.1 kg/cm²)
Pressure Min10 psig (0.67 kg/cm²)10 psig (0.67 kg/cm²)
Temperature Max (std)212°F (100°C)350°F (177°C)
Temperature Min (std)-30°F (-34°C)-80°F (-62°C)

Options Index

Option CodeDescription
Option IGas service calibration — specify gas type, inlet temperature, and pressure when ordering
Option NAmmonia service — stainless steel construction, EPR seals, gasketed case
Option R2Remote readout for bronze body — separates dial from meter body for high-temperature steam service
Option R3Remote readout for 316SS body — separates dial from meter body for high-temperature steam service
Option W24–20 mA two-wire transmitter — loop-powered, integral to meter housing
Option W34–20 mA transmitter with local digital display
Option RW3Self-contained 2-wire loop-powered transmitter and digital display in one unit
Option DR-1Remote digital display — connects to any W, W2, W3, or RW3 transmitter output
Option 1S2One SPDT Flo-Gard™ reed switch — independently adjustable setpoint
Option 2S2Two SPDT Flo-Gard™ reed switches — two independently adjustable setpoints
Option ISIntrinsically safe reed switch — CSA/NRTLc AEx ia IIC, Class I Div I Groups A–D; ATEX Zone 0
Option LEDLED flow status indicator — at-a-glance viewing and easy field calibration (no charge)

Services Not Recommended

  • Resins, paints or monomers which can form solid deposits in the piping system
  • "Super-solvents" which attack most available elastomers
  • Sulfuric acid in any concentration
  • Foams which tend to have inconsistent densities
  • Toxic substances requiring hermetically sealed enclosures
  • Fluids with viscosity above 500 centipoise
  • Pumping systems using piston pumps which produce non-steady flow conditions
  • Gravity-fed systems having less head than the pressure loss across the meter at normal operating conditions