RCM Liquid Flow Meters — Flo-Gage™ Series 7000 & 8000 — Northeast Controls Inc.

RCM Flow Meters

Liquid Flow Meters

Flo-Gage™ Series 7000 & 8000 · 4 GPH – 3,000 GPM · Water, Oil, Glycol & More

RCM Liquid Flow Meters — Flo-Gage™

RCM liquid flow meters have been developed for industrial applications where durability and reliability are important considerations in the monitoring of flow. The Flo-Gage™ operates on a classic differential pressure (ΔP) principle, similar to an orifice-plate meter but fully integrated for simplicity and reliability.

The Flo-Gage has accuracy for most industrial processes and is particularly suited for applications where compactness, low cost, minimal maintenance and resistance to accidental damage are important factors.

Suitable for potable and non-potable water, irrigation water, glycol-water mixtures, fuel oils, lubricating oils, gasoline and many other low and medium viscosity liquids (maximum viscosity 500 centipoise).

RCM Flo-Gage liquid flow meter — 316SS NPT body with polycarbonate dial housing, GPM scale, SP.GR.=1.0

Flo-Gage™ — 316SS NPT Body, GPM Scale

4 GPH – 3,000 GPM
Liquid flow range
±3% F.S.
Accuracy
1/4" – 8"
Meter sizes
2–3 Weeks
Standard lead time

Standard Features

  • Sturdy in-line metal construction to withstand piping stresses without breaking
  • Black on white dial — won't crack, glaze or become hard to read with age
  • Expanded 3.5″ (90mm) 270° analog dial for reading at a glance
  • Suitable for use with both opaque and clear fluids
  • Measures 6:1 range with ±3% F.S. Accuracy, 1% Repeatability
  • Dial and case factory configured for quick installation — easily field re-configured if needed
  • No external power, no separate orifice plates, no equalizing or blocking valves required
  • Available in Threaded (Series 7000) and Wafer (Series 8000) body styles
  • Offered in Bronze, 316SS & Monel

Specifications

SpecificationStandardOptional
SeriesSeries 7000 (FNPT threaded)Series 8000 (Wafer, 150/300 class flanges)
HousingUV Stabilized PolycarbonateAluminum
BodyBronzeMonel / 316SS
BellowsBronzeMonel / 316SS / Inconel
SealsBuna NViton / EPR / Teflon
CrystalPolycarbonateGlass
Gear MovementBronze316SS
Accuracy±3% F.S.±3% F.S.
Repeatability±1% F.S.±1% F.S.
Maximum Pressure180 psig (12.6 kg/cm²)400 psig (28.1 kg/cm²)
Minimum Pressure10 psig (0.67 kg/cm²)10 psig (0.67 kg/cm²)
Maximum Temperature212°F (100°C)350°F (177°C)
Minimum Temperature-30°F (-34°C)-80°F (-62°C)

Standard Liquid Flow Ranges (Water)

Meter SizeFlow Range (US)Flow Range (SI)
1/4"0.5 – 3 GPH2 – 11 l/h
3/8"1 – 6 GPH4 – 23 l/h
1/2"4 – 25 GPH15 – 95 l/h
3/4"10 – 60 GPH38 – 227 l/h
1"1 – 6 GPM4 – 23 l/m
1-1/2"2 – 15 GPM8 – 57 l/m
2"5 – 30 GPM19 – 114 l/m
3"15 – 100 GPM57 – 379 l/m
4"30 – 200 GPM114 – 757 l/m
6"100 – 600 GPM379 – 2,271 l/m
8"500 – 3,000 GPM1,893 – 11,356 l/m

Ranges shown for water at standard conditions. Custom calibrations available for any fluid — specify fluid, temperature, and pressure when ordering.

Typical Applications

HVAC

Chilled water and hot water loop monitoring in commercial buildings

Chemical Processing

Solvent, acid, and reagent flow measurement in batch processes

Food & Beverage

Cooling water, glycol, and process liquid monitoring

Pharmaceutical

Purified water (PW) and WFI distribution systems

Oil & Gas

Lube oil, hydraulic fluid, and fuel oil monitoring

Water Treatment

Chemical dosing and process water flow verification

Manufacturing

Coolant flow monitoring on CNC machines and heat exchangers

Power Generation

Cooling water and condensate return monitoring

Option: Liquid Ammonia Service

Liquid ammonia is used in industrial cooling systems, fertilizer and NOx emissions applications. Liquid ammonia service flow meters are constructed of stainless steel with EPR seals and a gasketed case, developed for industrial applications where durability and reliability are important considerations.

Installation Guidelines

Straight Pipe Upstream

Provide 10 diameters of straight pipe in front of the meter for accurate measurement.

Control Valves

Install control valves or solenoid valves downstream of the meter if possible.

Minimum Flow

The minimum flow rate which can be read is approximately 15% of full scale.

Best Accuracy

Select a flow range which will permit normal operation in the upper half of the meter scale.

Services Not Recommended

  • Resins, paints or monomers which can form solid deposits in the piping system
  • "Super-solvents" which attack most available elastomers
  • Sulfuric acid in any concentration
  • Foams which tend to have inconsistent densities
  • Toxic substances requiring hermetically sealed enclosures
  • Fluids with viscosity above 500 centipoise
  • Pumping systems using piston pumps which produce non-steady flow conditions
  • Gravity-fed systems having less head than the pressure loss across the meter at normal operating conditions

Standard Lead Time

2–3 Weeks

QuickShip Option

3–4 Business Days ARO

Nominal charge — covers groups of up to 5 meters