Tel: Us 1-201-419-6111 or sales@nciweb.com


 

How to Size a Non Electric Pump

Sizing Your Fluid Recovery Pump EXAMPLE
1.    What is the desired lbs./hr. of fluid to be pumped? 2800 Ibs./hr. 25 PSIG 15 PSI*
2.    What is the available motive gas or steam pressure?
3.    What is your total lift or back pressure?

Total lift and back pressure is the total pressure that the pump will be working against. This includes changes in fluid elevation, check valve cracking pressures, and any minor losses due to the piping system. A one foot change in elevation is equivalent to a .5 PSI back pressure.

Total Lift or Back Pressure = (.5 x Total Feet of Lift) + Minor Losses of Piping

*Example           Vertical lift = 28 ft.     Minor Losses  = 1 PSI
   *Total Lift or Back Pressure = (.5 x 28) + 1 = 15 PSI
4.    With the above specifications and a minimum of a 12-inch filling head, select the pump from the table below. Find 25 PSIG Operating Inlet Pressure.   Then, find 15 PSI Total Lift or Back Pressure. You can see that a 1 inch check valve kit will allow you to achieve the 2800 Ib./hr. pumping rate you desire.

OPERATING

TOTAL LIFT OR BACK

CHECK VA LVE & PIPING SIZE

INLET PRESSURE

PRESSURE

 

PSIG

BAR

PSIG

BAR

1"

1-1/2"

2" STD.

2" H.C.

 

 

15

1.0

3640

6580

9380

15,820

125

8.6

40

2.8

3360

6300

8820

14,840

 

 

60

4.1

3220

6020

8400

14 280

 

 

15

1.0

3640

6440

9240

15,680

100

6.9

40

2.8

3360

5880

8540

14,560

 

 

60

4.1

3080

5040

8120

13 860

 

 

15

1.0

3500

5880

9240

15,680

75

5.2

40

2.8

3360

5320

8120

13,720

 

 

60

4.1

2800

4760

7000

11900

 

 

10

0.69

3360

5600

8960

15,120

50

3.4

25

1.7

3220

5180

8120

13,720

 

 

40

2.8

2800

4480

6720

11480

 

 

5

0.34

3220

5880

8540

14,560

25

1.7

10

0.69

2940

5460

7840

13,440

 

 

15

1.0

2800

4620

7140

12180

10

.69

2

0.14

2800

4620

7140

12,180

 

 

5

0.34

2520

4060

5740

9,800

5

.34

2

0.14

2240

3780

5400

8,600

CHECK VALVE PIPING SIZE

FILLING HEAD SIZE & CONVERSION FACTOR

6" 152 mm

12" 305 mm 24" 610 mm  36" 914 mm

1"

1½"

2" Std.

2" High

.70 X

1.0 X 1.2 X 1.35 X

.85 X

1.0 X 1.2 X 1.35 X
Pump Capacities

In pounds per hour for liquids of 0.9 to 1.0 specific gravity (lower on request), with 12" filling head installed as recommended above pump top. Inlet port 3" N.P.T.; Outlet port 2" N.P.T. Optional ports and check valves available.

For capacities in GPM, multiply Ibs./hr. by .002. For Kg/hr., multiply by .454. For liquid specific gravities below .9, call the factory.  