HICORP 6-Way Opposite-Side Transfer Valve — Continuous Flow — Northeast Controls Inc.

HICORP Transfer Valves

6-Way Configuration

6-Way Opposite-Side Continuous Flow Transfer Valve

Zero Leakage · Opposite-Side Porting · API 614 Compliant

Opposite-Side Porting — Flexible Installation

Inlet on One Side, Outlets on the Opposite Side

The 6-Way Opposite-Side configuration places the common inlet on one face of the valve body and both equipment-train outlets on the opposite face. This suits installations where the supply header and the two equipment trains (filters, coolers, or pumps) approach from opposite directions, reducing the need for elbows and crossover piping.

The positive mechanical shoe-seal system provides true zero-leakage shutoff in both positions. Changeover is accomplished without shutdown, pressure loss, or the need for spectacle blinds.

Sizes: 1½″ through 6″
Connections: ANSI 150# · 300# · Butt-Weld
Body: Carbon Steel · 304L / 316L SS
Max Pressure: 675 PSI (300# / BW)
Seals: Buna-N · Viton® · Neoprene
Compliance: API 614
HICORP 6-way opposite-side porting transfer valve installed in industrial piping

6-Way Opposite-Side Porting

Standard Features

  • Inlet on one side, both outlets on the opposite side
  • Positive mechanical shoe-seal — zero leakage in both positions
  • Continuous flow changeover — no shutdown or pressure loss
  • Stainless steel operating shaft and internal mechanism
  • Low operating torque — manual or actuated operation
  • API 614 designed and tested
  • Flanged (150# / 300#) or butt-weld connections
  • Internals interchangeable with HYCOA JR-33
HICORP 6-Way Opposite-Side Transfer Valve dimensional drawing — three views showing inlet port #1, outlet port #6, ports #2–#5, equalizing/fill line, gauge ports, and labeled dimensions A–F

Approximate Dimensions

All dimensions in inches. Consult factory for certified drawings.

Valve SizeABCDEFG (150#)G (300#)Weight
1½″6-3/8124-7/1620-3/1610104476 lb
2″6-3/4144-7/1620-3/1612144899 lb
3″ (150#)7-3/4121722-3/414144N/A161 lb
3″ (300#)8-1/212-3/417-3/423-1/41414N/A8210 lb
4″10-1/415-5/821-7/828-3/42116-3/488254 lb
6″ (150#)11-1/218-3/1626-1/833-1/162619-3/4N/AN/A431 lb
6″ (300#)1319-3/1627-5/834-1/82619-3/4N/A12545 lb

Contact factory for certified configuration-specific drawings.

Pressure & Temperature Ratings

Pressure Ratings
150# ANSI Flange260 PSI — CS @ 200°F
300# ANSI Flange675 PSI — CS @ 200°F
Butt Weld675 PSI — CS @ 200°F
Temperature Ratings
Viton®350°F max
Neoprene250°F max
Buna-N200°F max

Operating Instructions

1

Open equalizing/fill line valve and allow pressure to balance.

2

Turn "T" handle counterclockwise ≈6–7 turns.

3

Push ball handle down to unseat shoes.

4

Rotate ball handle 180° (red arrow points to active ports).

5

Release ball handle and hand-tighten "T" handle clockwise (20 in-lb max).

6

Close equalizing valve.

Ready to specify the 6-Way Opposite-Side Valve?

Contact Northeast Controls for sizing assistance, certified drawings, or a quotation.