Contact Our Magnesonics Sales Team: 201-419-6111 or sales@nciweb.com


Page 1 of 3 Page 2 of 3 Page 3 of 3

Ordering Information

Typical Model
  BC 4F SA4 N 1 D4 /C 27
  Cage Chamber Enclosure Approval No. Switch Welding Process
    Type     of Mechanism   Connection
    M.O.C.     Switches     Style
Table No. 1 2 3 4 5 6 7 8
 
(1) External Cage Specifications

BC

XC

 

Minimum S.G.

Pressure Rating

Minimum S.G.

Pressure Rating

Model

SPDT

DPDT

100°F

750°F

Model

SPDT

DPDT

100°F

750°F

BCIF

.70

.74

350

275

XCIF

.70

.74

285

95

BC2F

.55

.57

300

235

XC2F

.55

.57

285

95

BC3F

.60

.62

600

465

XCSF

.60

.62

600

465

BC4F

.70

.72

1440

935

XC4F

.70

.72

740

505

BC5F

.65

.67

1000

780

XC5F

.70

.72

1440

935

BC6F

.35

.37

300

235

XC6F.35

.35

.37

285

95

BC7F

.45

.47

750

585

XC7F

.45

.47

740

505

BC8F

.60

.62

1000

780

XC8F

.60

.62

990

670

BC 9 F

.34

.34

450

350

XC9F

.34

.34

285

95

 
(2) Chamber Type and Material of Construction
Carbon Steel Stainless Steel
BC BS
Float is sealed inside chamber during manufacturing. 
Not removable.
Carbon Steel Stainless Steel
XC XS
Float may be removed from chamber for routine maintenance,
cleaning or inspection.
 
(3) Enclosure Types
  Duty Material of Cover Material of Base Material of Pressure Tube Material of Screwed Union Maximum Number of Switches
SA7 Explosion Proof Aluminum Alloy 316SS To Match Chamber 2 x 4 or 2 x 8 contacts
S17 Explosion Proof Cast Iron 316SS To Match Chamber 2 x 4 or 2 x 8 contacts
SA4 Explosion Proof Drawn Steel Aluminum Alloy 316SS To Match Chamber 2 x 4 or 2 x 8 contacts
 
(4) International Approvals (5) Number of Switch Mechanisms

U

Underwriters Laboratories

Cl. I, Div. 1, Grp. C & D

C

Canadian Standards Association

Cl. 1, Div. 1, Grp. C & D

B

BASEEFA/CENELEC

E Exd IIC T6: BS5501: Pts 1 & 5

H

Underwriters Laboratories

Cl. I, Div. 1, Grp. B,C& D

N

Weatherproof to NEMA 4X/IP66

U.L. CSA EANSW

Specify No. of Switches Required.
 
(6) Switch Mechanism Types
      AC max. values DC max. values
    Temp. Wetside °F VA Volts Amps Watts Volts Res. Amps Ind. Amps
D4 4 Contact 750 2000 440 5 50 250 5 0.5
X4 Link for SPDT 480 2000 440 10 50 250 10 0.5
H4 2 independent single 480 2000 440 10 50 250 10 0.5
P4 pole single throw contact sets 750 6 250 0.25 3.6 250 0.25 0.1
D8 8 Contact 750 2000 440 5 50 250 5 0.5
X8 Link for DPDT 480 2000 440 10 50 250 10 0.5
H8 4 independent single 480 2000 440 10 50 250 10 0.5
P8 pole single throw contact sets 750 6 250 0.25 3.6 250 0.25 0.1
 
(7) Welding Specification
Code design and construction standard on all chambers unless otherwise specified.
Code radiography is available on request.
circumferential and process connection welds are full penetration single-V butt welds.  All body flanges are weld neck.  Process flanges are slip on type, 1" NPS nipples as standard.
Welders qualified to A.S.M.E. IX.
P.W.H.T available on request.
 
(8) Process Connection Configuration and Rating
    Select 1 for Side & Bottom Select 2 for Side & Side with Drain
  0 1" N.P.T (Socket Weld Connection Use Code "s")
  1 1" Class 150 R. F. A.N.S.I B 16.5/B.S. 1560
1 2 1" Class 300 R. F. A.N.S.I B 16.5/B.S. 1560
or 3 1" Class 600 R. F. A.N.S.I B 16.5/B.S. 1560
2 4 1-1/2" Class 150 R. F. A.N.S.I B 16.5/B.S. 1560
  5 1-1/2" Class 300 R. F. A.N.S.I B 16.5/B.S. 1560
  6 1-1/2" Class 600 R. F. A.N.S.I B 16.5/B.S. 1560
  7 2" Class 150 R. F. A.N.S.I B 16.5/B.S. 1560
  8 2" Class 300 R. F. A.N.S.I B 16.5/B.S. 1560
  9 2" Class 600 R. F. A.N.S.I B 16.5/B.S. 1560
    Flange faces are raised face with serrated concentric or serrated spiral groove finish.
 
 
 
 
 