Dimensional and Operating Level Data |
|
|
|
|
Note: All flange nipples are 1" NPS
as standard |
Note: All flange nipples are 1" NPS
as standard |
|
|
A |
B |
C |
D |
E |
F |
|
Single |
Multi- |
(7) |
NPT |
Flanged |
Hi |
Single |
Multi- |
C-C |
Chamber |
Chamber |
Model |
Switch |
Switch |
Flanged |
or/SW |
Alarm |
Switch |
Switch |
Type B |
Type X |
BC1F & XCIF |
8-1/2 |
11-1/2 |
14 |
3-1/4 |
6 |
2 |
2-3/4 |
6-1/8 |
14 |
5-1/2 |
5-3/4 |
BC2F & XC2F |
10 |
13 |
14 |
3-3/4 |
6-1/2 |
2 |
2-3/4 |
6-1/8 |
14 |
6 |
6 |
BC3F & XC3F |
10 |
13 |
14 |
3-3/4 |
6-1/2 |
2 |
2-3/4 |
6-1/8 |
14 |
6 |
6-11/16 |
BC4F & XC4F |
10 |
13 |
14 |
3-3/4 |
6-1/2 |
2 |
2-3/4 |
6-1/8 |
14 |
6 |
8-1/16 |
XC5F |
10 |
13 |
14 |
3-3/4 |
6-1/2 |
2 |
2-3/4 |
6-1/8 |
14 |
6 |
8-1/16 |
BC5F |
9-1/2 |
12-1/2 |
14 |
4-1/4 |
7-1/2 |
2 |
2-3/4 |
6-1/8 |
14 |
6-1/2 |
8-1/16 |
BC6F & XC6F |
10 |
13 |
14 |
4-3/4 |
7-1/2 |
2 |
2-3/4 |
6-1/8 |
14 |
7 |
6-9/16 |
BC7F & XC7F |
10 |
13 |
14 |
4-3/4 |
7-1/2 |
2 |
2-3/4 |
6-1/8 |
14 |
7 |
7-3/8 |
BC8F & XC8F |
10 |
13 |
14 |
4-3/4 |
7-1/2 |
2 |
2-3/4 |
6-1/8 |
14 |
7 |
8-1/4 |
BC9F & XC9F |
12-1/2 |
15-1/2 |
16 |
5-3/4 |
8-1/2 |
2 |
2-3/4 |
6-1/8 |
14 |
7-1/2 |
7-3/16 |
Notes: |
1) Flanged dimensions
apply for R.F. process connections up to 2" -
600# |
|
2) Switch actuation levels
are at minimum S.G. |
|
3) C = Highest operating
liquid level |
|
4) D (Single Switch) =
Reset level |
|
5) D (Multi-Switch) =
Lowest operating liquid level |
|
6) D-C = Switching Differential
(Max.) |
|
7) Add 2" to "A" Dimension
for (2) Switches |
All dimensions are in
inches. Dimensions are for reference only and
must be certified upon order. |
|
|
|
|
Enclosure Dimensional Data |
Type |
Duty |
Height G |
Conduit Thread |
Switch Adjustment |
Weatherproof Rating |
SA7, SA17 |
Explosion Proof |
13-3/4" |
1" NPT |
3-3/8" |
NEMA 4X & 7 |
SA4 |
Weatherproof |
12" |
1" NPT |
3-3/8" |
NEMA 4X |
|
|
|
|
Materials of Construction |
Technical
Specification |
Designed in
accordance with B31.3 pressure tested to 1.5 x max
work press. |
Mat'l of Construction |
Carbon Steel Chamber |
Stainless Steel Chamber |
Chamber Tube |
ASTM A106 GrB/BS3602 HFS410 |
ASTM A312 T316/BS3605-316-514 |
Top/Bottom Caps |
ASTM A234/BS1504-161-430A |
ASTM A403 WP-316 |
Flanges/Fittings |
ASTM A105/BS1503-221-430E |
ASTM A182F316/BS1503-316-513 |
Studs |
ASTM A193-B7/BS1506-621A-B7 |
ASTM A193-B7/BS1506-621A-B7 |
Nuts |
ASTM A194-2H/BS1506-162-2H |
ASTM A194-2H/BS1506-162-2H |
Float & Trim |
T316 SST |
T316 SST |
|
|
|
|
Options |
Low temperature carbon steel chambers - Controls
to meet N.A.C.E. requirements - A comprehensive N.D.T. package. |
|
Warranty Statement |
All Magnesonics Corp. mechanical level devices
are warranted free of detects in materials and workmanship
for five years from the date of original factory shipment.
If
returned within the stated warranty period; and upon factory
inspection the cause of the claim is determined to be covered
under the warranty: at Magne-Sonic Corp.'s option, the device
will be repaired or replaced without
cost to the purchaser (or owner) other than transportation.
Magne-Sonic Corp. shall not
be liable for misapplication, labor claims, direct or
consequential damage or expense arising from the installation
or use of the equipment. There are no other warranties expressed
or implied. |
|
|
Previous Page |
|
|