Magnesonics
J200 · JMSVT · JMS100 · US601–US331 — Electronic Level Switches & Transmitters
Jerguson tuning fork, ultrasonic gap, and vibration rod level switches offer unsurpassed reliability in level switch applications for liquids and solids where mechanical linkages and moving parts are not acceptable. Available with FM, UL, and CSA approvals.
Vibrating tuning fork level switch for liquids and solids. No moving parts — the fork vibrates at its natural frequency; when submerged, the frequency shifts and triggers the output. Unsurpassed reliability where mechanical linkages and moving parts are not acceptable.
Approvals: FM, UL, CSA
Miniature direct load vibrating tuning fork level switch. Compact design for tight installations. Suitable for liquids and solids in tanks and vessels.
Approvals: FM, UL, CSA
Ultrasonic gap level switch for liquids. Transmitter and receiver are mounted across a small gap; liquid presence in the gap interrupts the ultrasonic beam and triggers the output. No moving parts, no contact with the process fluid.
Approvals: FM, UL, CSA
Vibrating probe level switch for bulk solid measurement. The probe vibrates at its natural frequency; when buried in solids, the vibration is damped and the output switches. Suitable for powders, granules, and bulk solids.
Approvals: FM, UL, CSA
Non-contact ultrasonic level switch. Transducer mounts on top of the tank; ultrasonic pulses detect the liquid surface. No wetted parts, suitable for corrosive and coating liquids.
Non-contact ultrasonic level transmitter with 2-wire or 3-wire output. Continuous level measurement with 4–20 mA output.
Ultrasonic level measurement and control for bulk solids applications.
Non-contact level and flow measurement controller for open channels and tanks.
Smart 2-wire ultrasonic level transmitter with HART communication for remote configuration and diagnostics.
2-wire explosion-proof ultrasonic level transmitter for hazardous locations.
Jerguson RF Capacitance level switches are designed for point level alarm or control of conductive and non-conductive liquids, granular materials, foams, pastes, slurries, and interface applications. Driven shield circuitry ignores conductive material build-up on the probe surface.
RF capacitance point level switch with driven shield circuitry that ignores conductive material build-up on the probe. For conductive and non-conductive liquids, granular materials, foams, pastes, slurries, and interface applications.
Adjustable RF capacitance level switch with field-selectable low or high level failsafe modes. Adjustable relay time delay to prevent chattering in turbulent applications.
Continuous RF capacitance level transmitter providing a 4–20 mA output. Compatible with any Jerguson insulated or driven shield level sensing probe.
1-201-419-6111 · [email protected]
Request PricingQuick RFQ
Request Pricing