PEECO Explosion Proof Flow Switches — Class I Div 1 Group D — Northeast Controls Inc.

PEECO Flow Switches

Explosion Proof Flow Switches

Explosion Proof · Class I, Division 1, Group D · NEMA 7

PEECO explosion proof flow switch

PEECO Explosion Proof Flow Switches

PEECO explosion proof flow switches are certified for use in hazardous (classified) locations where flammable gases, vapors, or combustible dusts may be present. The same proven PEECO flow-actuated mechanism is housed in a NEMA 7/9 explosion proof enclosure that contains any internal ignition and prevents propagation to the surrounding atmosphere.

Rated Class I, Division 1, Group D — built for hazardous environments where flammable gases or vapors demand the highest level of protection. Each switch is custom-engineered for the application — fluid, pipe size, pressure, temperature, and electrical requirements are specified at time of order.

Explosion ProofClass I, Division 1Group DNEMA 7

Specifications

Pressure Rating
To 600 PSI standard (higher pressures available)
Temperature Range
-450°F to +300°F standard; to +2,000°F with finned body extension
Pipe Sizes
1/16" to 12 ft. diameter or larger
Switch Action
SPDT standard; DPDT, SPST-NO, SPST-NC available
Electrical Rating
5A 125VAC / 3A 250VAC standard; custom ratings available
Enclosure
NEMA 7 (Class I, Div. 1, Group D)
Hazardous Location Rating
Class I, Division 1, Group D — Explosion Proof
Body Materials
Carbon steel, 316SS, Monel, Hastelloy, or any machinable metal
Wetted Parts
316SS standard; Teflon/PVC/Kynar coating optional
Connections
Screwed (NPT), flanged, tee, wafer, or welded

Hazardous Area Classifications Covered

Class I, Division 1 — Flammable Gases & Vapors

Locations where flammable gases or vapors are present in the air under normal operating conditions. Groups A, B, C, D. Typical: refineries, chemical plants, paint spray booths.

Class I, Division 2 — Flammable Gases & Vapors (Abnormal)

Locations where flammable gases or vapors are handled, processed, or used, but are normally in closed containers or systems. Groups A, B, C, D.

Typical Applications

  • Petroleum refinery process lines
  • Chemical plant hazardous areas
  • Offshore oil & gas platforms
  • Paint and coating operations
  • Grain elevator and flour mill facilities
  • Solvent storage and transfer systems
  • Natural gas processing plants
  • Petrochemical storage terminals

Custom-Engineered to Order

PEECO explosion proof flow switches are not off-the-shelf items. To request a quote, provide: fluid type, pipe size, flow rate range, operating pressure, operating temperature, electrical requirements (voltage, amperage, switch action), and hazardous area classification (Class, Division, Group). Contact Northeast Controls Inc. for application engineering assistance.