Series DA-7035-N temperature switches |
Series
DA-7035-N temperature switches include the same time-proven
switching mechanism used in our Series DA pressure switches.
Bourdon tube assures high sensitivity and long life. Fully
adjustable deadband makes units suitable for a wide range of
control applications. Visible, calibrated dial and external
adjustments make changing setpoints simple and fast. Dimensional Information

|
FEATURES: |
- Adjustable deadband
- Snap action switch standard
- Inert gas activated Bourdon tube
- No cross ambient temperature effects
- No bulb elevation correction required
- Visible dial calibrated in both °F and °C
- Visible on/off indication
|
| |
| PHYSICAL
DATA |
Service: Compatible liquids or gases.
Wetted Materials: Bulb and connection: 304 SS.
Temperature Limit: Process: see model chart, Ambient: 180°F (82°C).
Pressure Limit: 300 psi (20.6 bar).
Enclosure Rating: General purpose. Optional weatherproof and explosion-proof.
Repeatability: ± 1% of full scale.
Switch Type: SPDT snap switch. Optional DPDT snap and a variety of mercury switches.
Electrical Rating: 15A @ 120/240/480 VAC. 1/8 HP @ 120 VAC single phase. 0.5A @ 120 VDC resistive, 0.25A @ 240 VDC resistive.
Electrical Connections: Screw terminal.
Conduit Connection: 7/8" (22.23 mm) hole for 1/2" (12.7 mm) conduit hub.
Process Connection: 3/4" male NPT. Other sizes available.
Mounting Orientation: Vertical and level.
Set Point Adjustment: External knobs for set point and reset point.
Weight: 5 lb (2.3 kg).
Deadband: Adjustable from minimum in model chart to full range. Optional low fixed deadband.
Capillary: 6 ft (1.8 m) standard. Ranges 1N – 7N, and 10N: copper. Ranges 8N, 9N, 11N: 304 SS.
Set Point Scale: Indication in °F and °C.
Options: See switch type, see enclosures, fixed deadband, longer or shorter capillary, armored capillary, wells, two stage, 1/2" or 1" connection sizes, manual reset, and other bulb styles.
Agency Approvals: UL. |
| |
| Popular Models: |
| Model Number |
Range °F (°C) |
Max. Temperature - °F(°C) |
Min. Dead Band °F(°C) |
Min. Insertion Depth "E" - in. (mm) |
| DA-7035-153-1N |
-60 to +30 (-50 to 0) |
150 (65) |
23 (13) |
2-7/8 (73) |
| DA-7035-153-3N |
0-100 (-18 to 40) |
240 (115) |
25 (14) |
2-7/8 (73) |
| DA-7035-153-4N |
50-150 (10-65) |
250 (120) |
25 (14) |
2-7/8 (73) |
| DA-7035-153-5N |
100-200 (40-95) |
300 (150) |
25 (14) |
2-7/8 (73) |
| DA-7035-153-7N |
140-300 (60-150) |
500 (260) |
41 (23) |
2-7/8 (73) |
| DA-7035-153-8N |
250-415 (120-215) |
550 (290) |
42 (23) |
2-7/8 (73) |
| DA-7035-153-9N |
350-550 (175-290) |
600 (315) |
50 (28) |
4-7/8 (124) |
| DA-7035-153-10N |
100-300 (40-150) |
500 (260) |
50 (28) |
2-7/8 (73) |
| DA-7035-153-11N |
100-500 (40-260) |
600 (315) |
100 (56) |
2-7/8 (73) |
|
|
|
| 1 All
bulbs, including those with a copper capillary, are made of
304 stainless steel. |
| 2 Insertion
depth can be increased through use of bulb supports or wells.
Consult factory. |
| |
| Previous Page |
| |
| |