Love Series 16S Temperature/Process Controller

1/16 DIN, Universal Input, Isolated Outputs, Fuzzy Logic, Self-Tune® PID
 

The 16S Series temperature/process controls offer universal input (10 thermocouple types, 4 RTD types, voltage, and current), single or dual set point, alarm (optional), Fuzzy Logic, Selftune, Peak/Valley indication, Percent Output indication, Heater Break protection, Auto/Manual capability, and 16 Segment Ramp and Soak with adjustable time base and assured soak.

Options for the 16S include Process Output Retransmission (Voltage or Current), Remote Analog Set Point (Voltage, Current, Resistance), RS-232 Serial Communication, RS-485 Serial Communication, and 4-Stage Set Point. See Dimensional Information

SPECIFICATIONS
Front Panel Selectable Inputs:
Thermocouple, RTD, DC Voltage, or DC Current (See Input Ranges below).
Input impedance:
Thermocouple = 3 Megohms minimum. Voltage = 5000 ohms. Current = 10 ohms. RTD current = 200 µA maximum.
Scaling for Current and Voltage Inputs: minimum of 100 counts placed anywhere between -1999 to +9999, maximum of -1999 to +9999. Scale low and scale high points are selected independently.
Output Ratings:
SSR: 2.0 A at 240 VAC resistive at 77°F (25°C). De-rates to 1.0 A at 130°F (55°C). Minimum load of 100 mA. DC SSR: 1.75 A at 32 VDC maximum. Relay: SPST, 3A at 240 VAC resistive, 1.5 A @ 240 VAC inductive. Pilot Duty rating: 250 VA, 2 A @ 120 VAC, 1 A @ 240 VAC. Alarm Relay: SPST, 3 A @ 240 VAC resistive; 1.5 A @ 240 VAC inductive. Pilot Duty Rating: 240 VA, 2 A @ 120 VAC or 1 A @ 240 VAC. Switched Voltage: 15 VDC at 20 mA. Proportional Current: 0 to 20 mADC, scalable, into 600 ohms maximum.
Power Consumption: 5 VA maximum.
Supply Voltage: 100 to 240 VAC nominal, +10% -15%, 50 to 400 Hz single phase; 132 to 240 VDC +10% -20%.
Accuracy: ±0.25% of span ±1 least significant digit.
Display: two four-digit LED displays, 0.3 in (7.62 mm) high.
Display Resolution: 1 degree or 0.1 degree (sensor dependent), or 1 count.
Serial Communications (Optional): RS-232 or RS-485 with either LoveLink™ or Modbus® RTU protocol.
Operating Temperature Range: 14 to 131°F (-10 to 55°C).
Storage Temperature Range: -40 to 176°F (-40 to 80°C).
Humidity Range: 0 to 90% up to 104° F (40°C) non-condensing.
Weight: 8 oz (227g).
Front Panel Rating: Type 4X (IP66).
Agency Approvals: UL E83725, CE.
Input Ranges:
INPUT TYPE RANGE °F RANGE °C
Type J or L1 Thermocouple -100 to +1607 -73 to +871
Type K1 Thermocouple -200 to +2500 -129 to +1371
Type T1 Thermocouple -350 to +750 -212 to +398
Type E1 Thermocouple -100 to 1800 -73 to +932
Type R Thermocouple 0 to 3200 -17 to +1760
Type S Thermocouple 0 to 3200 -17 to +1760
Type B Thermocouple +75 to +3308 +24 to +1820
Type C Thermocouple 0 to 4208 -17 to +2320
Type N1 Thermocouple -100 to +2372 -73 to +1300
100 Ohm Plt. 0.00385 DIN1 RTD -328 to +1607 -200 to +875
100 Ohm Plt. 0.00392 Nist1 RTD -328 to +1607 -200 to +875
120 Ohm Nickel 0.00628 US1 RTD -112 to +608 -80 to +320
1000 Ohm Plt. 0.00385 DIN1 RTD -328 to +1607 -200 to +875
Current/Voltage/ΔVoltage2 Scalable Units from -1999 to +9999
FEATURES
  • Fuzzy logic with Self Tune®
  • Loop break protection
  • Universal input, isolated outputs
  • Peak/valley indication
  • Percent output indication
  • Four password protected security levels
  • 16 segment ramp/soak function with assured soak
  • Illuminated keypad
 
OPTIONS

924** Analog Remote Set Point, 0 to 10 VDC
926** Analog Remote set Point, 0 to 20 mADC
928** Analog Remote Set Point, 0 to 10,000 ohms
934** Process Signal Output, PV or SV. Isolated 0 to 20 mADC
936** Process Signal Output, PV or SV. Isolated 0 to 10 VDC
948 4-Stage Set Point
992** RS-485 Computer Compatible Control - Lovelink™ Protocol
993** RS-232 Computer Compatible Control - Lovelink™ Protocol
995** RS-232 Computer Compatible Control - Modbus® Protocol
996** RS-485 Computer Compatible Control - Modbus® Protocol
9502 12-24 VDC/VAC power input

**These options may not be combined with each other. Option 948 can be combined with options 934, 936, 992 or 9502 only.

 
Popular Models:
Model Number
 16S020
 16S050
 16S111
 16S120-9502
 16S122
 16S130
 16S133
 16S150
 
Model Chart:
Example 16S 0 1 0 Series 16S010 Temperature/Process Controller, SSR Output A
Series 16S       Series 16S Temperature/Process Controller
Alarm  

0
1

    No
Yes
Output A     1
2
3
4
5
8
 

SSR
15 VDC Pulsed
Relay, Form A
Relay, Form B
Current
DC SSR

Output B       0
1
2
3
4
5
8
None
SSR*
15 VDC Pulsed
Relay, Form A
Relay, Form B
Current
DC SSR
 
 
 