Series 8600 Temperature Process Controller |
Series
8600 Temperature/Process Controllers are compact and versatile
with a choice of horizontal and vertical mount housings.
They set a new standard for quality, ease-of-use and value.
While a high level of standard features are included, many function
setup items appear in the control menu only when the function
is selected, so you don't have to wade through unnecessary items.
Units feature a universal input for thermocouple types J, K,
E, T, L, N, B, C, S & R; RTD's - 100W Pit. NIST, 100W Pit.
DIN, 120W Ni Industrial, 1000W Pit, DIN; differential input
(-10 to +10 mV DC) and process input (0 to 20 mA DC, 0 to 10
VDC). A standard 24 volt isolated, regulated power supply is
included to operate most standard 4-20 mA transmitters.

Standard features include Self-Tune®, Fuzzy Logic, fully adjustable
PID, Auto/Manual control with bumpless transfer and front panel
activation key, percent output indication, peak and valley indication,
liip break protection and indication. For process inputs, the
display is fully programmable from -1999 to +9999 with selectable
decimal point location. Most thermocouple and RTD inputs can
show shole or tenth degree displays. The Series 8600 is available
with single or dual setpoint outputs and can be programmed for
on-off, PID or heat/cool or latching alarm. All outputs are
isolated form the inputs. Outputs include 10 amp relay, 2.5
amp SSR and 0-20 mA DC (scaleable). 15 VDC SSR drive is standard.
Optional dual alarms are fully programmable. |
| |
| See
Dimensions |
| |
| Popular Models |
Model |
Alarm |
Output
A |
Output
B |
D86010-(1)(0)
D86030-(1)(0)
D86050-(1)(0)
D86110-(1)(0)
D86130-(1)(0)
D86150-(1)(0)
D86111-(1)(0)
D86133-(1)(0) |
NO
NO
NO
YES
YES
YES
YES
YES |
SSR
RELAY
CURRENT
SSR
RELAY
CURRENT
SSR
RELAY |
NONE
NONE
NONE
NONE
NONE
NONE
SSR
RELAY |
|
| Note: Specify suffix 1 for horizontal or 0 for
vertical mounting. |
| |
| More Standard Features |
NEMA 4X (IP 65) Front Panel Resists
Dust & Moisture
. Four Password Protested Security Levels
. Front Panel Programmability
. 16 Segments of Ramp/Soak with Program End Control
. Operates on 100-240 VAC, 132-240 VDC |
| |
| PHYSICAL DATA |
| Front Panel Selectable
Inputs: |
|
Thermocouple, RTD, DC voltage or DC current. |
| Input Impedance: |
|
Thermocouple - 3 megohms minimum
Voltage - 5000 ohms Current - 10
ohms RTD Current - 200mA maximum |
| Display: |
|
Two 4 digit, 7 segment LED; 0.4"
(10 mm) high - horizontal models; 0.3" (7.62 mm)
high -vertical models |
| Accuracy: |
|
±0.25% of span, ±1 least significant
digit |
| Supply Voltage: |
|
100 to 240 VAC nominal, +10%-15%, 50
to 400 Hz, single phase; 132 to 240 VDC +10%-20% |
| Operating Temperature
Range: |
|
14 to 131°F (-10 to 55°C) |
| Control Output Ratings: |
|
SSR: 2.5 A at 240 VAC resisting
at 77°F (25°C). De-rate to 1.25 A at 130°F (55°C)
Relay: SPDT, 10 A at 240 VAC resistive,
½ hp at 120 VAC, ½ hp at 240 VAC Alarm Relay:
SPST, 3 A at 240 VAC resistive Switched Voltage:
15 VDC at 20 mA Proportional Current:
0-20 mA DC, scaleable into 600 ohms maximum. |
| Weight: |
|
13 oz. (369 g) |
|
| |
| SUGGESTED SPECIFICATIONS |
| Process Controller shall be microprocessor based
of 1/8 DIN size with dual four digit LED displays and accuracy
of ±0.25% of span, ±1 least significant digit. PID control will
Self-Tune® automatically and Fuzzy Logic software shall be included.
Selectable inputs and associated impedance to be thermocouple
(3 megohms min.), RTD current (200mA max.), current (10 ohms)
and voltage (5000 ohms). Sealed front panel shall have NEMA
4X (IP 65) rating. Outputs shall be selectable for relay logic,
current, voltage or switched voltage. Electronics replaceable
without wiring changes via removable front panel. Process controller
shall be Dwyer Model D86 _____. |
| |
|