Contact Dwyer Sales Department: 1-201-419-6120  |  dwyer@nciweb.com


Dwyer Series TSP

Liquid Flow Controller
NO or NC Relay Output, Adjustable Time Delay

Dwyer Series TSPProtect pumps and valves from dry running with the Series TSP Liquid Flow Controller. The Series TSP combine a liquid flow switch with a fail-safe relay controller to detect a flow or no flow situation and provides switching for direct actuation of pumps and valves. Controller features adjustable time delay, selectable NO or NC operation, and LED indication of sensor, relay, and power status. Four models (TSP110S, TSP210S, TSP120S, TSP220S) are designed with an integral flash alarm to provide immediate indication of local alarm conditions.

Service: Compatible liquids.
Wetted Materials: Polypropylene/PPS or Polyvinylidene Fluoride.
Temperature Limits: -40 to 158°F (-40 to 70°C).
Pressure Limits: 150 psi (10 bar) @ 77°F (25°C), derated 1.67 psi (.113 bar) per °C above 25°C.
Relay Output: 1 SPDT Form C, isolated and sealed.
Relay Load: 250 VAC, 10 A resistive, 1/2 hp.
Switching Mode: Selectable NO or NC.
Supply Voltage: 120/240 VAC, 50/60 Hz, selectable.
Current Consumption: .25 amps maximum.
Sensor Voltage Supply: 13 VDC, 1 Watt max., nominal.
Sensor Trigger Point: Dry <10 mA, wet >10 mA.
Time Delay: Adjustable, 0.15 to 60 seconds.
Flash Type*: Xenon tube.
Flash Frequency*: 1 per second.
Brightness*: >50,000 CP.
Strobe Life*: 10 M cycles.
Conduit Connection: 1/2" NPT.
Mounting Connection: 3/4" NPT.
Enclosure: Polypropylene, flame retardant, probe NEMA 4X/IP65.
Agency Approvals: CE.
*Applies to models with flash alarm only.

Model Number Description Lead Time
TSP110 Liquid flow controller, PP wetted parts, .7" (1.8 cm) sensor. Stock
TSP210 Liquid flow controller, PVDF wetted parts, .7" (1.8 cm) sensor. 3-4 Weeks
TSP120 Liquid flow controller, PP wetted parts, 2.1" (5.3 cm) sensor. Stock
TSP220 Liquid flow controller, PVDF wetted parts, 2.1" (5.3 cm) sensor. 3-4 Weeks
TSP110S Liquid flow controller, PP wetted parts, .7" (1.8 cm) sensor, with flash alarm. 3-4 Weeks
TSP210S Liquid flow controller, PVDF wetted parts, .7" (1.8 cm) sensor, with flash alarm. 3-4 Weeks
TSP120S Liquid flow controller, PP wetted parts, 2.1" (5.3 cm) sensor, with flash alarm. 3-4 Weeks
TSP220S Liquid flow controller, PVDF wetted parts, 2.1" (5.3 cm) sensor, with flash alarm. 3-4 Weeks