Javascript Menu by Deluxe-Menu.com
HOME | SEARCH | HELP | CONTACT  
Live Help
search us
Product Menu
  Blancett Index
  B2800 Flow Monitors
  Model 1100
  CorrExx & Model 1200
  FloClean / 3-A Sanitary
  Model 200
  Model 500
  Model 900
  QuikSert Models
  B1750 PD Flow Meter
  Frequency Converters
  K-Factor Scalers
  Request Pricing
sitemap
 
blancett
 
 

 

CorrExx Turbine Flow Meter

The CorrExx Turbine Flow Meter was developed for applications requiring compatibility in high corrosive, temperature and pressure environments.


Simple in design and construction, the CorrExx Flow Meter utilizes both an upstream and downstream flow straighter for a high  degree of flow accuracy. The meter produces an AC sinewave signal proportional to its volumetric flow rate. With optional electronics, it will interface with most instruments and computers.

Highlights:
Corrosive-resistant body and rotor-bearing components compatible with most chemical environments.
Can be used in high temperature (300+° F, 149° C) and pressure (5000 psi) applications.
Small size allows for installation in confined areas.
Can be mounted horizontally or vertically without affecting meter accuracy.
Available outputs: Magnetic sinewave, amplified DC frequency or analog (4-20mA)
NIST traceable calibrations.
Manufactured in USA
 
Specifications:
Materials: Body & internal wetted parts: 316LSS | Bearings: Fluorosint® (Teflon®/mica)
Flow Range: 0.5 - 4.0 GPM (LPM)
Accuracy: ± 1% of reading
Repeatability: ± 0.1%
Calibration: Water proven (NIST traceable) 1900 ppg typical K-factor
Pressure Drop: <2 psi at maximum flow rate
Pressure Rating: 5000 psi (maximum)
Turbine Temperature: + 300° F (149° C)
End Connections: 1/2" male NPT standard.
Weight: 0.5 lbs.
 
Outputs:
Standard:
Magnetic Sensor: Minimum 20 mV peak-to-peak sine wave at minimum flow rate. This variable reluctance Magnetic Pickup coil is designed to exceed the performance and application criteria of standard or modified magnetic pickups.
Specifications  
DC Coil Resistance: High Sensitivity: 1.5K ohm
Output: 20mV to 30Vp-p Sine Wave
Connector: 2-pin gold plated type to mate with MS 3106-10SL-4S or equivalent.
Temperature Rating: -250° to +300° F (-157° to 149° C)
Material of Construction: 303/304 Stainless Steel shell, epoxy encapsulated (all standard connectors have gold plated pins.
See Picture of Standard Magnetic Sensor
 
Optional Active Sensor:
Surface mount circuit converts the sine wave output of a magnetic pickup to a 4-20mA analog signal. The modular design eliminates the need to wire an accessory converter. Standard and special shielded cables are available.
Specifications  
Excitation Range: 5 to 28 Vdc
Output Current Range: 4-20mA
Minimum Load Resistance: 10 ohm
Maximum Load Resistance* 0.02 (*including line losses)
Circuit Power Requirement: Load + 7.0 mA
Accuracy: ± 0.5% of full scale span, plus accuracy of input source.
Cable Connection: 3 pin Amphenol Tuchel
Temperature Rating: 131° F (55° C)
Approvals: CE Certified Heavy Industrial
  En 50081-2 EMC Emissions
  En 50082-2 EMC Immunity
Materials of Construction: Mag Pickup Housing - 304SS
  Sensor Housing - Ni Plated Aluminum
See Picture of Optional Active Sensor
 
Optional Amplified Frequency:
This Pre-Amplifier operates with the standard magnetic pickup where input frequency levels exceed 1.5 Vp-p. This Pre-Amp outputs stable square wave pulses, thus extending the application range and signal distance of the pickup coil.
Specifications:  
Input Voltage: 10 to 18 Vdc
Input Current: 15 mA
Input Sensitivity: 5 mV
Output Voltage: 10 Vp-p
Frequency Range: Near Zero to 5 kHZ
Distance pickoff/Pre-Amp 5,000 ft. Max. (30.5m)
Temperature Range: -20° to 160° F (-29 to +71° C)
 
Ordering Information:
Part # Flow Range (GPM) K-Factor Impulse /cc Fluid Ports (NPT) Filtration (micron) Pressure Rating (psi max)
Aluminum Housing
B175-A20 0.01-2.00 13,900 3.67 1/4" 30 5,000
B175-A60 0.05-20.0 1,850 0.49 1/2" 50 5,000
B175-A80* 0.5-60.0 1,630~ 0.43 1-1/4" 200 5,000
Stainless Steel Housing
B175-S20 0.01-2.00 13,900 3.67 1/4" 30 5,000
B175-S60 0.05-20.0 1,850 0.49 1/2" 50 5,000
B175-S80* 0.5-60.0 1,630~ 0.43 1-1/4" 200 5,000

Magnetic Pick-up Sold Separately:
B170109 Standard, will interface with all Blancett electronics
B170210 with Preamplifier Optional

* Must use B170210 Magnetic Pick-up with Preamplifier

 
Previous Page
 
 
 
Northeast Controls Incorporated
Tel: 1-201-327-7660 | Fax: 1-201-327-3242 | email: sales@nciweb.com
123 Pleasant Avenue - Upper Saddle River - New Jersey 07458 USA